Lot  12  pcs . x 6F1P (6Ф1П) = ECF80 = 6BL8 = 6AX8  NEW 


Some Tubes can be of different years of manufacture and different manufacturers. 


TECHNICAL DATA 6F1P

Triode - pentode.
Designed to work in the local oscillators, converters and voltage amplifiers, high frequency and pulse circuits of scanning in television receivers.
Durability not less than 1500 hours.
Weight not more than 20 g.
Specifications and electric parameters lamp 6Ф1П:
Filament voltage 6.3 ± 0.6 V
Filament current 430 ± 25 mA
Triode part:
Anode voltage nominal (constant) 100 V
The anode voltage limit (DC) 250 V
The cathode current 14 mA limit
Grid voltage (constant) -2 V
The power dissipated by the anode limit is 1.5 W
The voltage between cathode and heater limit (DC) 100 V
The steepness of the characteristic is 5 ± 1.5 mA/V
A gain of 20
The resistance in the grid circuit limit 0.5 Mω
The input capacity of 2.5 ± 0.5 pF
The output capacitance is about 0.3 pF
Throughput capacity 1.45 ± 0.35 pF

Pentode part:
The anode voltage nominal (DC) 170 To
The anode voltage limit (DC) 250 V
The anode current of 10.5 ± 3.5 mA
The cathode current 14 mA limit
Voltage grid of the first (permanent) -2 In
The second grid voltage nominal (DC) 170 To
Grid current second not more than 4 mA
The power dissipated by the anode limit 2.5 W
Power dissipated by the second grid, the limit of 0.7 W
The power dissipated by the anode, the total, maximum 4.5 W
The steepness of the characteristic is 6.2 ± 2.2 mA/V
The internal resistance of 0.4 Mω
Resistance in the price of the first grid limit of 1 MW
The equivalent resistance of 1.5 kω vnutrishnih noise
Input capacitance 5.5 ± 1 pF
Output capacity 3.4 ± 0.6 pF

IMPORTANT INFORMATION! BE SURE TO READ BEFORE ORDERING! 

In the title of the lot is the name of the vintage Soviet tube and after the symbol ~ the name of the Western analog. Be careful! Soviet tubes are only approximate analogs of Western tubes and match pinout, but are not exact copies of Western tubes. Testing Soviet tubes with Western-made tube testers can sometimes show unreliable results. Programs (Cards) designed for testing Western tubes can sometimes show unreliable results and erroneously show that the tube is not good enough. But these are unreliable results and should be disregarded. The volt-ampere characteristics of Soviet tubes are different from their Western analogs!

Use for testing exclusively testers with programs for testing Soviet tubes.


If you would like to get the datasheet for the Soviet tubes in this lot, please send me a message before you place your order and I will send you a JPG datasheet for the Soviet tube.


Also, do not test vintage tubes with modern digital pulse powered tube testers. Use only testers with a classic power supply. For reliable measurement results, warm up each tube for at least 5 minutes prior to measurement.


I do not accept any claims on the quality of tubes if you test purchased Soviet tubes of this lot on testers with programs (modes) of testing Western tubes or test tubes on digital testers with pulse power supply.


Dear customer, you can combine shipping buying more than one lot.
If You need more than one lot, or another quantity - please contact. 
Also please check other available items. 